Aboveground Storage Tanks

Newberry manufactures its full line of aboveground storage tanks in-house, from 70 gallon fire pump day tanks up to 20,000 gallons in the published tables, with larger sizes available on request. Every steel tank is built, tested, and labeled to UL-142, with UL-2085 fire-protected and STI-certified Flameshield and F921 options where code requires them. We have been building steel tanks for 100 years, and expedited shipping options are available from our location in America’s distribution center.

Whether you need secondary containment for an SPCC plan, a 2-hour fire rating for a fueling island, a skid tank that can be moved when empty, or a vertical oil field tank, the line is below. Sizing questions go to our tank chart calculator. For code questions, confirm requirements with your local authority having jurisdiction, then call us with the spec.

Credentials bullets:

  • 100-year track record in steel tank manufacturing
  • UL-142 listed across all standard aboveground steel lines
  • UL-2085 fire-protected tanks (Fireguard)
  • STI-SPFA certified, subject to independent quality control inspections
  • Extended warranty eligible on STI-certified tanks
  • PEI member company

Master capacity table

Find your capacity, then the line that carries it. Ranges below reflect published tables; larger sizes are available on request.

Product LineCapacity RangeStandardWall
Fire Pump Tanks70 to 700 galUL-142SW / DW
Obround Tanks275 galSteel, UL-142 constructionSW / DW
Roth Double Wall Tanks110 to 400 galUL SU2258Double wall
Poly Tanks32 to 330 galUL rated food grade polyethyleneContainment vessels available
Rectangular Tanks (Slim, Bulk, Catwalk)Pending consolidationUL-142SW / DW
Farm Fuel Tanks150 to 2,000 galStandard constructionSingle wall
Bracket UL-142 Tanks150 to 2,000 galUL-142SW / DW
Vertical & Oil Field Tanks300 to 15,000 galUL-142SW / DW
Fireguard UL-2085300 to 20,000 galUL-2085 / UL-142 / STI F941Double wall
Flameshield & F921300 to 20,000 galUL-142 / STIDouble wall
Skid Tanks150 to 20,000 galUL-142SW / DW
Saddle UL-142 Tanks3,000 to 20,000 galUL-142SW / DW
Containment Dikes300 to 2,000 gal tank110% containmentn/a

Explore Our Aboveground Tank Lines

UL-142 Standard Tanks

UL-142 is the baseline standard for aboveground storage of flammable and combustible liquids. Every Newberry UL-142 tank is all-steel construction, available in single wall or double wall, and ships standard with one coat of gray primer. Double wall provides secondary containment without a separate dike.

Bracket & Saddle UL-142 Tanks

The core aboveground line. Bracket tanks (150 to 2,000 gallons) sit on leg brackets; saddle tanks (3,000 to 20,000 gallons) sit on saddles for larger bulk storage. Commonly used for petroleum fuel and lubricant oil storage. Sizes up to 30,000 gallons in single wall vertical construction are available on request.

Bracket (150 to 2,000 gal)

Capacity (Gallons)Inner Tank Dimensions InchesWeights (lbs) SW (DW)Download (SW)Download (DW)Interested in Purchasing?
15030 x 48300 (500) download button download buttonBuy Now
30038 x 60450 (775) download button download buttonBuy Now
50045½ x 72700 (1100) download button download buttonBuy Now
55048 x 72750 (1200) download button download buttonBuy Now
100045½ x 1441450 (2050) download button download buttonInquire Now
100048 x 1321450 (2050) download button download buttonInquire Now
110048 x 1441500 (2150) download button download buttonInquire Now
200064 x 1442200 (3750) download button download buttonInquire Now

Saddle (3,000 to 20,000 gal)

Capacity (Gallons)Inner Tank Dimensions (Inches)Weights (lbs) SW (DW)Download (SW)Download (DW)Interested in Purchasing?
300064 x 2163350 (5200) download button download buttonInquire Now
400064 x 2884027 (6574) download button download buttonInquire Now
400096 x 1325000 (7500) download button download buttonInquire Now
600096 x 1926625 (10120) download button download buttonInquire Now
800096 x 2568478 (12450) download button download buttonInquire Now
1000096 x 32410250 (14500) download button download buttonInquire Now
1200096 x 38411500 (17000) download button download buttonInquire Now
15000120 x 31214000 (22000) download button download buttonInquire Now
20000120 x 40817500 (28000) download button download buttonInquire Now

Skid Tanks

Heavy-duty aboveground storage on skid runners, 150 to 20,000 gallons. Double wall skid tanks are convenient where secondary containment is required. Commonly used for fuel and lubricant oil storage. Optional colors and coatings available.

Skid tanks are built in two mounting configurations. Tanks from 150 to 2,000 gallons use runner skids with forklift pockets, so the tank can be lifted and repositioned on site with equipment you already have. Tanks from 3,000 to 20,000 gallons use I-beam skids, which carry the greater weight but do not include forklift pockets and require rigging to place.

Runner skid with forklift pockets (150 to 2,000 gal)

CapacityInner DimsWeight SW (DW)
15030 x 48400 (425)
30038 x 60365 (670)
55048 x 72800 (925)
100045 x 1441500 (2025)
100048 x 1321500 (2025)
200064 x 1442300 (3950)

I-beam skid, no forklift pockets (3,000 to 20,000 gal)

CapacityInner DimsWeight SW (DW)
300064 x 2163400 (5250)
400064 x 2885150 (7500)
600096 x 1926675 (11100)
800096 x 2568625 (14500)
1000096 x 32410350 (17250)
1200096 x 38412750 (20000)
15000120 x 31215860 (24790)
20000120 x 40820848 (29200)

Vertical & Oil Field Tanks

Vertical tanks meet UL-142 for aboveground storage of flammable and combustible liquids, 300 to 15,000 gallons, single or double wall. Vertical oil field tanks are custom-designed for oil field service, and vertical orientation saves footprint where floor space, not height, is the constraint.

Capacity (Gallons)Inner Tank Dimensions (Inches)Weight (lbs) SW (DW)Download (SW)Download (DW)Interested in Purchasing?
30038 x 60420 (775) download button download buttonBuy Now
55048 x 72750 (1275) download button download buttonBuy Now
100064 x 721238 (2100) download button download buttonInquire Now
200064 x 1442200 (3750) download button download buttonInquire Now
400096 x 1324400 (6750) download button download buttonInquire Now
600096 x 1925900 (9420) download button download buttonInquire Now
800096 x 2567750 (12100) download button download buttonInquire Now
10000120 x 2048320 (14150) download button download buttonInquire Now
12000120 x 2469500 (16000) download button download buttonInquire Now
15000120 x 31211750 (20100) download button download buttonInquire Now
20000126 x 37210500 (17750) download button download buttonInquire Now

Fire Pump Tanks

Day tanks for fire pump fuel systems, 70 to 700 gallons, single or double wall. Built, tested, and labeled per UL-142 with standard NPT fittings and leg bracket configuration as specified. Exterior red oxide primer.

CapacityInner DimsWeight SW (DW)
7024 x 36205 (311)
11524 x 60303 (425)
14024 x 72363 (536)
25032 x 72437 (710)
35038 x 72505 (844)
50048 x 65650 (968)
70048 x 90922 (1653)

Farm Fuel Tanks

Single wall carbon steel tanks for gasoline, diesel, and other farm-use fuels, 150 to 2,000 gallons, in skid or bracket configuration. The award-winning skid design uses a balanced, no-swing geometry and forklift pockets, so the tank can be lifted and moved when empty with equipment already on the farm, without bringing in a rental crew. Larger sizes are available up to 20,000 gallons for bulk farm storage. Also used for non-potable water, chemicals, and other liquids compatible with carbon steel. Subjected to factory leakage test; one-year manufacturer’s limited warranty.

Capacity (Gallons)Inner Tank Dimensions (Inches)Approx. Weight (lbs)BracketSkidInterested in Purchasing?
15030 x 48260 (288) download button download buttonBuy Now
30038 x 60366 (410) download button download buttonBuy Now
50045½ x 72500 (N/A) download button download buttonBuy Now
55048 x 72540 (583) download button download buttonBuy Now
100045½ x 1441012 (1106) download button download buttonInquire Now
100048 x 1321012 (1106) download button download buttonInquire Now
200064 x 1442037 (2128) download button download buttonInquire Now

Obround Tanks

Space-saving 275 gallon steel tanks for lubricant and motor oil dispensing, available with 3-inch, 6-inch, or 19-inch rise brackets so the tank clears equipment underneath.

Capacity (Gallons)Inner Tank Dimensions (Inches)Approx. Weight (lbs)Download Drawings
27527 x 44 x 60 6″ Rise290 download button
27527 x 44 x 60 19″ Rise290 download button
27529 x 39 x 60 3″ Rise350 download button
27529 x 46 x 60 3″ Rise800 download button

Fire-Rated and Fire-Protected Tanks

When code requires fire protection, the standard determines the tank. Fireguard is a UL-2085 insulated, fire-protected tank. Flameshield is a 2-hour fire-tested tight-wrap double wall tank. Both go beyond what UL-142 alone provides. Confirm which standard your local authority having jurisdiction requires before ordering.

Fireguard UL-2085 Tanks

Thermally insulated, double wall, fire-protected aboveground tanks from 300 to 20,000 gallons. Conform to UL-2085 for insulated secondary containment aboveground tanks, built to UL-142 and NFPA 30 and 30A codes, meet IFC and CARB Standing Loss Control air emissions requirements, and comply with STI Standard F941. Available in rectangular and vertical construction. Options include internal compartment bulkheads, emergency vents, remote overfill, gauges, pumps, pump platforms, canopies, spill containment, ladders, seismic support designs, and turnkey assembly and installation.

Capacity (Gallons)Inner Tank Dimensions (Inches)Approx. Weight (lbs)Download (Drawings)Interested in Purchasing?
30038 x 602700 download button Buy Now
55048 x 723350 download button Buy Now
100048 x 1324800 download button Inquire Now
200064 x 1447800 download button Inquire Now
300064 x 21610300 download button Inquire Now
400096 x 13214647 download button Inquire Now
600096 x 19219722 download button Inquire Now
800096 x 25624022 download button Inquire Now
1000096 x 32429122 download button Inquire Now
1200096 x 38433422 download button Inquire Now
1400096 x 45640106 download button Inquire Now
15000120 x 31236800 download button Inquire Now
20000120 x 40845900 download button Inquire now

Flameshield & F921

Both are STI/SPFA certified double wall steel tanks, 300 to 20,000 gallons, meaning production is subject to independent quality control inspections and the tank is eligible for an extended warranty. Flameshield uses a tight-wrap double wall design with 2-hour fire-tested performance, built-in secondary containment, and STI Flameshield and Southwest Research Institute identification labels. F921 is a double wall steel design with impermeable secondary containment meeting EPA SPCC requirements. Both meet UL-142 and are commonly used for petroleum fuel and lubricant oil storage. Sizes up to 30,000 gallons in single wall vertical construction are available on request.

Capacity (Gallons)Inner Tank Dimensions (Inches)Approx. Weight (lbs)Download DrawingsInterested in Purchasing?
30038 x 60775 download button Buy Now
55048 x 721200 download button Buy Now
100048 x 1322050 download button Inquire Now
200064 x 1443750 download button Inquire Now
300064 x 2165200 download button Inquire Now
400064 x 2886574 download button Inquire Now
400096 x 1327750 download button Inquire Now
600096 x 19210120 download button Inquire Now
800096 x 25612450 download button Inquire Now
1000096 x 32414500 download button Inquire Now
1200096 x 38417000 download button Inquire Now
15000120 x 31222000 download button Inquire Now
20000120 x 40828000 download button Inquire Now

Rectangular, Roth, and Poly Tanks

Not every aboveground application calls for a cylindrical steel tank. Newberry also builds rectangular tanks for lubricant storage and dispensing in shops, service bays, and warehouse footprints; Roth double wall tanks certified to UL SU2258 from 110 to 400 gallons; and stackable poly tanks and gravity feed systems from 32 to 330 gallons, which store bulk fluids vertically to free up floor space in quick lube shops, dealerships, fleet maintenance facilities, and manufacturing plants.

Choosing a Standard

Most aboveground buying decisions come down to what your local authority having jurisdiction requires. Confirm the requirement with them first. The table below is a general guide to how Newberry lines map to common requirements; it is not a substitute for the AHJ’s determination, and local code takes precedence in every case.

If you need...ConsiderWhy
Baseline aboveground storageAny UL-142 tank, single wallMeets the standard, lowest cost
Secondary containment for SPCCDouble wall UL-142, F921, or a containment dike110% containment without a separate basin
A 2-hour fire ratingFlameshieldTight-wrap double wall, fire-tested
Fire protection plus insulationFireguard UL-2085Insulated, IFC and CARB emissions compliant
Oil field serviceVertical oil field tankVertical orientation saves footprint
Containment for a tank you already ownContainment DikeRetrofits existing single wall tanks
Lubricant storage in a shop or bayRectangular, Roth, or polyFits working footprints; see the lube oil page

Still deciding between standards? Our breakdown of UL-142 vs UL-2085 vs UL-2080 walks through what each standard covers and when code requires it. To convert a fluid level into gallons, use our tank chart calculator.

Containment Dikes

Secondary containment for new or existing single wall tanks, sized to contain a minimum of 110 percent of tank capacity. A solution for SPCC requirements that also provides visual leak detection. Constructed on sturdy I-beam supports, standard with one coat of gray primer, with optional industrial enamel in gray or white and more color options available.

Tank CapacityContainment CapacityContainment DimensionsApprox. Weight (lbs)Download DrawingsInterested in Purchasing?
30033080 x 48 x 20484 download button Buy Now
55060596 x 72 x 22862 download button Buy Now
10001100168 x 72 x 241620 download button Inquire Now
20002200192 x 96 x 282643 download button Inquire Now

Turnkey Packages

Turnkey packages ship pre-assembled with the pumps, vents, gauges, and dispensing equipment already installed, which removes the time and expense of fitting a tank out on site. Standard package sizes are available to order directly. Larger tanks and aboveground rectangular setups are more complex and less likely to fall into a standard pattern, so those are quoted to your configuration.

Tank CapacityContainment CapacityContainment DimensionsApprox. Weight (lbs)Download DrawingsInterested in Purchasing?
30033080 x 48 x 20484 download button Buy Now
55060596 x 72 x 22862 download button Buy Now
10001100168 x 72 x 241620 download button Inquire Now
20002200192 x 96 x 282643 download button Inquire Now

FAQ

What is an aboveground storage tank?

An aboveground storage tank, or AST, is a fuel or oil storage vessel installed at or above grade rather than buried. ASTs are governed primarily by UL-142 for flammable and combustible liquids, with additional standards such as UL-2085 applying where fire protection is required. Newberry manufactures aboveground tanks from 70 gallon fire pump day tanks up to 20,000 gallons in the published tables, with larger sizes available on request.

What is the difference between UL-142 and UL-2085?

UL-142 is the baseline standard for aboveground steel tanks storing flammable and combustible liquids. UL-2085 covers insulated, fire-protected tanks with secondary containment, which is what Fireguard tanks are built to. Which standard applies to your installation is determined by your local authority having jurisdiction, so confirm the requirement with them before you purchase.

What size aboveground fuel tanks are available?

Newberry aboveground tanks run from 70 gallon fire pump day tanks up to 20,000 gallons in the published tables, with sizes up to 30,000 gallons in single wall vertical construction available on request. Farm tanks cover 150 to 2,000 gallons in the published tables with larger sizes available, and skid tanks cover 150 to 20,000 gallons.

Do I need a double wall tank or a containment dike?

Both provide secondary containment for SPCC compliance. A double wall tank has an integral outer shell, which saves footprint and installation labor. A containment dike is an external basin that can be added to a single wall tank you already own, and it allows visual leak detection. Newberry dikes are sized to hold a minimum of 110 percent of tank capacity. Your local authority having jurisdiction determines which is acceptable for your site.

What is a Fireguard tank?

Fireguard is a thermally insulated, double wall, fire-protected aboveground tank conforming to UL-2085. Newberry Fireguard tanks are also built to UL-142 and NFPA 30 and 30A, meet IFC and CARB Standing Loss Control air emissions requirements, and comply with STI Standard F941.

What is the difference between Flameshield and F921?

Flameshield uses a tight-wrap double wall design with 2-hour fire-tested performance and built-in secondary containment. F921 is a double wall steel tank with impermeable secondary containment meeting EPA SPCC requirements but without the fire rating. Both are STI/SPFA certified and eligible for an extended warranty.

Can a skid tank be moved with a forklift?

Skid tanks from 150 to 2,000 gallons are built on runner skids with forklift pockets, so an empty tank can be lifted and repositioned with equipment already on site. Tanks from 3,000 to 20,000 gallons are built on I-beam skids, which do not include forklift pockets and require rigging to place.

Are aboveground fuel tanks available for farms?

Yes. Newberry farm fuel tanks are single wall carbon steel tanks from 150 to 2,000 gallons in skid or bracket configuration, for gasoline, diesel, and other farm-use fuels, with larger sizes available up to 20,000 gallons for bulk farm storage. The skid design includes forklift pockets, so an empty tank can be moved with equipment already on the farm rather than a rental crew.

Does Newberry manufacture its own tanks?

Yes. Newberry has manufactured steel tanks for 100 years at facilities in West Memphis, Arkansas and Memphis, Tennessee. Production of STI-certified tanks is subject to independent quality control inspections.

Can I get an aboveground tank with the pump already installed?

Yes. Turnkey packages ship with pumps, vents, gauges, and dispensing equipment pre-installed, which removes the time and expense of fitting the tank out on site. Standard package sizes can be ordered directly; larger and rectangular configurations are quoted to your setup.